Start here › Generators
Generators and transfer switches in Akron
Checked November 16, 2026 · independent guide, not an electrician
Safety first. If you see sparks, smell burning or a power line is down, stay away and call 911. Report power outages to Ohio Edison at 1-888-544-4877. If you smell gas, leave, and from outside call 911 and your gas utility (Enbridge Gas Ohio's emergency line is 1-877-542-2630). (FirstEnergy, Downed Power Lines; FirstEnergy, Outage Help; Enbridge Gas Ohio, Report Gas Emergency)
Backup power is a safety project before it is a comfort project. A generator wired the wrong way can kill a line worker restoring power on your street, and one run in the wrong place can poison the people inside the house. This page covers what Ohio Edison and FirstEnergy require, how the Summit County permit fits in, and the national cost data.
Safety lines
Why Akron households think about backup power
Ohio Edison serves Akron and lists neighborhoods including East Akron, Ellet, Goodyear Heights, Kenmore and North Hill in its Summit County tree-trimming work. The company says trees are a leading cause of power outages and times its trimming for the spring and summer storm season. (Ohio Edison tree-trimming release) FirstEnergy lists severe weather and vehicle accidents as common outage causes. (FirstEnergy, Outage Help)
For most homes, the case for backup power comes down to a few loads: a sump pump in a wet basement, a furnace blower in winter, a refrigerator, and any medical equipment. If someone in the house depends on electrically powered life-support equipment, FirstEnergy runs a Critical Care list, but it says listing does not guarantee faster restoration and it advises a contingency plan such as battery backup. (FirstEnergy, Outage Help)
Rule one: no generator connects to house wiring without an isolation device
FirstEnergy is explicit. Never connect a generator, portable or stationary, directly to your home's electrical system without a proper isolation device, which it describes as a switch that disconnects the house from the utility's lines while the generator runs, and the reverse. It says to have a qualified electrician install that device, because a generator feeding house wiring that is still connected to the grid "could start a fire and/or electrocute a service crew member." (FirstEnergy, How to Safely Operate a Backup Generator)
That rules out plugging a generator into a dryer or wall outlet to power the house. FirstEnergy calls this "backfeeding" and says it is extremely dangerous to utility workers and to neighbors on the same circuit, and that it bypasses household circuit protection. (FirstEnergy)
FirstEnergy's rule covers both kinds of generator:
- Portable generators. The generator runs outside. If it powers house circuits, it connects through an isolation device such as a transfer switch, installed by an electrician.
- Stationary (standby) generators. A fixed unit needs the same isolation. Gas-fired units also need gas piping, covered below.
Rule two: carbon monoxide
FirstEnergy says generator exhaust contains high levels of carbon monoxide (CO), which can kill. Its rules:
- Never run a generator inside the home, and not in partly enclosed spaces even with fans or open doors.
- Place it outside, away from windows, doors and vents, and point the exhaust away.
- Install CO alarms throughout the home, because CO cannot be seen, smelled or tasted.
- Turn the generator off and let it cool at least two minutes before refueling, and never store fuel inside.
- Run it on a dry surface, and use heavy-duty outdoor extension cords rated above the total load.
Source: FirstEnergy, How to Safely Operate a Backup Generator.
FirstEnergy lists headache, dizziness, nausea, fainting, shortness of breath and weakness as signs of CO poisoning. If you notice them, get to fresh air immediately and call 911. Do not go back to shut the generator off. (FirstEnergy)
Gas-fired standby generators
A natural gas standby unit needs a gas line. Summit County bars homeowners from doing gas piping work beyond flexible appliance connections. It must be done by a state-licensed contractor. (Summit County Codified Ordinances 1305.06) The County also says a homeowner can pull a permit for most work "EXCEPT gas lines." (Summit County Building Standards)
If you smell gas near a generator or meter, leave the area. From a safe place, call 911 and your gas utility. Enbridge Gas Ohio's emergency line is 1-877-542-2630. Enbridge says not to operate switches, phones or anything that can spark near a suspected leak. (Enbridge Gas Ohio, Report Gas Emergency) Before any trench for a gas line or buried cable, call Ohio811 by dialing 811 at least two full working days before you dig. (Enbridge Gas Ohio)
Permits in Akron
Generator and transfer switch wiring inside Akron goes through the Summit County Division of Building Standards, after the City's Akron Approval. (City of Akron, Plans and Permits) The County's published residential electrical fees start with a $60 application fee, plus $12 per miscellaneous circuit and $40 per service upgrade item, and a 1% state fee. (Summit County, Electrical Permit Application) The form says to call for any fee not listed. A standby generator's gas piping and pad may need separate permits, so ask the contractor to list every permit in the quote.
What it costs (national figures)
No published Akron-specific generator prices were found. Angi's 2026 national figures:
| Item | National range |
|---|---|
| Install a generator transfer switch | $400 to $2,500 |
| Install a whole-house generator | $1,540 to $8,740 |
| Typical electrician hourly rate | $50 to $100 |
Source: Angi, How Much Does an Electrician Cost. Angi's table also lists transfer switches at $200 to $400 as a project type, lower than its install range above. This guide treats the $400 to $2,500 figure as the installed cost.
Questions for the installer
- What isolation device will you install, and does FirstEnergy's guidance cover it?
- Which circuits will the generator carry, and does that include the sump pump and furnace?
- Who pulls the Summit County permit, and is gas work included?
- Where will a portable unit sit when it runs, and how far is that from windows and doors?
Frequently asked questions
Is it legal to backfeed through a dryer outlet?
FirstEnergy says never to power home wiring by plugging a generator into a wall outlet. (FirstEnergy)
Can I run a generator in my garage with the door open?
No. FirstEnergy says not to run one in partly enclosed spaces, even with doors and windows open. (FirstEnergy)
Who reports the outage while my generator runs?
Report it to Ohio Edison at 1-888-544-4877 or text OUT to 544487. (FirstEnergy, Outage Help)
Verify before you hire
Sources
- FirstEnergy, How to Safely Operate a Backup Generator
- FirstEnergy, Outage Help
- https://www.firstenergycorp.com/outages_help/outage_help/downed-power-lines.html
- Ohio Edison tree-trimming release
- Enbridge Gas Ohio, Report Gas Emergency
- Angi, How Much Does an Electrician Cost
- Summit County, Electrical Permit Application
- Summit County Building Standards
- Summit County Codified Ordinances 1305.06
- City of Akron, Plans and Permits